''Nuclear Technology, VOL. 157 JAN. 2007.'' The purpose of this article is to show that when the half-life of a specimen being measured is comparable to the dead time of the measurement system, an additional correction is required in the classical dead-time correction formula for a nonparalyzing detector. This additional correction accounts for the decay of radioactivity during the dead time, and therefore the expression for the additional correction includes the specimen half-life. This additional correction is significant for some specialized applications involving very short-lived nuclides. These results may be useful for neutron activation analysis of short-lived isotopes and certain medical imaging applications.</p></span></span>[[Category:Scientific Paper]]
+
''Nuclear Technology, VOL. 157 JAN. 2007.'' The purpose of this article is to show that when the half-life of a specimen being measured is comparable to the dead time of the measurement system, an additional correction is required in the classical dead-time correction formula for a nonparalyzing detector. This additional correction accounts for the decay of radioactivity during the dead time, and therefore the expression for the additional correction includes the specimen half-life. This additional correction is significant for some specialized applications involving very short-lived nuclides. These results may be useful for neutron activation analysis of short-lived isotopes and certain medical imaging applications.</p></span></span>
 +
 
 +
[[Category:Scientific Paper|dead-time correction nonparalyzing detectors measuring short-lived nuclides]]
  
 
[[Category:New Energy]]
 
[[Category:New Energy]]

Revision as of 10:13, 1 January 2017

Scientific Paper
Title Dead-Time Correction for Nonparalyzing Detectors When Measuring Short-Lived Nuclides
Author(s) Andrija Radovic
Keywords {{{keywords}}}
Published 2007
Journal None
Volume 157
No. of pages 4
Pages 106-109

Abstract

Nuclear Technology, VOL. 157 JAN. 2007. The purpose of this article is to show that when the half-life of a specimen being measured is comparable to the dead time of the measurement system, an additional correction is required in the classical dead-time correction formula for a nonparalyzing detector. This additional correction accounts for the decay of radioactivity during the dead time, and therefore the expression for the additional correction includes the specimen half-life. This additional correction is significant for some specialized applications involving very short-lived nuclides. These results may be useful for neutron activation analysis of short-lived isotopes and certain medical imaging applications.