Difference between revisions of "M?ssbauer Experiment In A Rotating System On The Second Order Doppler Shift: Confirmation of The Corrected Result By K?ndig"

From Natural Philosophy Wiki
Jump to navigation Jump to search
(Imported from text file)
 
(Imported from text file)
 
(One intermediate revision by the same user not shown)
Line 8: Line 8:
 
==Abstract==
 
==Abstract==
  
We present results of M?ssbauer experiment in a rotating system, whose performance was stimulated by our recent finding (<em>Phys. Scr.</em>, 77 (2008) 035302) and which consisted in the fact that a correct processing of&nbsp; K?ndig's&nbsp; experiment&nbsp; data&nbsp; on&nbsp; the&nbsp; subject&nbsp; gives&nbsp; an&nbsp; appreciable&nbsp; deviation&nbsp; of&nbsp; a&nbsp; relative&nbsp; energy shift (Delta E)/E between emission and absorption resonant lines from the standard prediction based on the relativistic dilation of time (that is&nbsp; (Delta E)/E = -v<sup>2</sup>/(2c<sup>2</sup>) to the accuracy c<sup>-2</sup>, where v is the tangential velocity of absorber of resonant radiation, and c is the light velocity in vacuum). Namely, the K?ndig result we have corrected becomes&nbsp; (Delta E)/E = -kv<sup>2</sup>/(2c<sup>2</sup>), with k=0.596?0.006 (instead of the result k = 0.5003?0.006, originally reported by K?ndig). In our own experiment we carried out measurements for two absorbers with substantially different isomer shift, which allowed us to make a correction of M?ssbauer data regarding vibrations in the rotor system at various rotational frequencies. As a result we got the overall estimation k = 0.68?0.03.[[Category:Scientific Paper]]
+
We present results of M?ssbauer experiment in a rotating system, whose performance was stimulated by our recent finding (<em>Phys. Scr.</em>, 77 (2008) 035302) and which consisted in the fact that a correct processing of&nbsp; K?ndig's&nbsp; experiment&nbsp; data&nbsp; on&nbsp; the&nbsp; subject&nbsp; gives&nbsp; an&nbsp; appreciable&nbsp; deviation&nbsp; of&nbsp; a&nbsp; relative&nbsp; energy shift (Delta E)/E between emission and absorption resonant lines from the standard prediction based on the relativistic dilation of time (that is&nbsp; (Delta E)/E = -v<sup>2</sup>/(2c<sup>2</sup>) to the accuracy c<sup>-2</sup>, where v is the tangential velocity of absorber of resonant radiation, and c is the light velocity in vacuum). Namely, the K?ndig result we have corrected becomes&nbsp; (Delta E)/E = -kv<sup>2</sup>/(2c<sup>2</sup>), with k=0.596?0.006 (instead of the result k = 0.5003?0.006, originally reported by K?ndig). In our own experiment we carried out measurements for two absorbers with substantially different isomer shift, which allowed us to make a correction of M?ssbauer data regarding vibrations in the rotor system at various rotational frequencies. As a result we got the overall estimation k = 0.68?0.03.
  
[[Category:Relativity]]
+
[[Category:Scientific Paper|m ssbauer experiment rotating second order doppler shift confirmation corrected result k ndig]]
 +
 
 +
[[Category:Relativity|m ssbauer experiment rotating second order doppler shift confirmation corrected result k ndig]]

Latest revision as of 19:43, 1 January 2017

Scientific Paper
Title M?ssbauer Experiment In A Rotating System On The Second Order Doppler Shift: Confirmation of The Corrected Result By K?ndig
Author(s) Alexander L Kholmetskii, Tolga Yarman
Keywords {{{keywords}}}
Published 2009
Journal None

Abstract

We present results of M?ssbauer experiment in a rotating system, whose performance was stimulated by our recent finding (Phys. Scr., 77 (2008) 035302) and which consisted in the fact that a correct processing of  K?ndig's  experiment  data  on  the  subject  gives  an  appreciable  deviation  of  a  relative  energy shift (Delta E)/E between emission and absorption resonant lines from the standard prediction based on the relativistic dilation of time (that is  (Delta E)/E = -v2/(2c2) to the accuracy c-2, where v is the tangential velocity of absorber of resonant radiation, and c is the light velocity in vacuum). Namely, the K?ndig result we have corrected becomes  (Delta E)/E = -kv2/(2c2), with k=0.596?0.006 (instead of the result k = 0.5003?0.006, originally reported by K?ndig). In our own experiment we carried out measurements for two absorbers with substantially different isomer shift, which allowed us to make a correction of M?ssbauer data regarding vibrations in the rotor system at various rotational frequencies. As a result we got the overall estimation k = 0.68?0.03.